Alstre
Try it
03 · Measurements

Category-specific attributes

A window needs completely different data from a garage door, so each category has its own set of fields. We show them with examples, explain how the work is split between the sales adviser and the surveyor, and describe the warnings for unusual values.

Why separate sets of fields

If the form showed all fields at once, the surveyor would scroll through dozens of questions, most of which have nothing to do with what is in front of them. That is why an item shows only the fields of its own category.

Name, room, quantity, unit and note are common to all. The rest changes with the category — and that is what decides whether the measurement is enough to order the goods or whether you will have to call the customer.

Example: window

Opening type
Tilt-and-turn, turn-and-tilt, side-hung, top-hung, fixed or sliding.
Number of sashes and direction
How many separate sections the window has and the opening side of each sash — written the way it is said on site: “L+R” or “L+fixed+R”.
Glazing unit
Double, triple or quadruple glazing, acoustic, anti-burglary.
Uw coefficient
Heat transfer of the whole window, in W/m²K.
Profile system
Typed in by name, for example “Veka SoftLine” or “Aluplast Ideal 8000”.
Trickle vent
None, humidity-controlled, pressure-controlled or mechanical.
Details
External colour, if different from the internal one; number of anti-lift locking points; drip cap in millimetres; glazing bars; warm edge spacer.

What the other categories ask

It is best seen in what external doors and shading ask for — each of these fields settles something that cannot be filled in later over the phone:

Entrance door
Leaf thickness and wall depth, hinge side, opening direction, transom and sidelight dimensions, and burglar-resistance class from RC1 to RC4.
Garage door
Garage depth, headroom and free space on both sides of the opening — these determine the track type. In addition, the panel design, the operator with its brand and number of remotes, and a wicket door with its own dimensions.
Roller shutter
Mounting type (surface-mounted, concealed, top-mounted, in a cassette), box size, colours of the curtain, box and guide rails, control type from cord to radio motor, and the control side.
Internal sill
Thickness, nose overhang, edge finish and end caps — left and right separately.
Floor panels
Thickness and abrasion class from AC3 to AC6. No dimensions are taken — the item is counted in square metres.
The type narrows the conversation
Besides attributes, every category also has a type: entrance doors can be steel, aluminium, timber or PVC, and an external roller blind can be surface-mounted, concealed, fabric, Roman or day-night.

Field types

  • Drop-down list — where the answers can be counted: RC class, control type, glazing unit.
  • Number with a unit — millimetres for dimensions, W/m²K for coefficients.
  • Yes / no — glazing bars, warm edge, operator, wicket door.
  • Text — proper names: profile system, operator brand, colour.

Some fields have a hint explaining why they are measured — the headroom field says plainly that it affects the garage door track type. It is guidance for a new surveyor, not decoration.

Who fills in which field

Some fields are a sales decision, not a measurement. The system keeps them apart: the Uw coefficient and the profile system are set by the sales adviser in the showroom, while wall depth, headroom and free space by the opening are measured by the surveyor on site.

This way nobody in the field has to guess what was agreed in the sales conversation, and nobody in the office has to call around for dimensions.

Warnings for unusual values

The fields have rules attached that react to values outside the typical range — there are more than thirty of them. They do not check whether the measurement is “correct”: they flag what most often turns out to be a mistake or a costly misunderstanding.

Technical requirements
A Uw coefficient above 1.1 W/m²K does not meet the 2021 building regulations (WT 2021); for external doors the limit is Ud 1.3.
Inconsistent data
A double-glazed unit rarely goes below Uw 1.3 — such a combination usually means someone copied a parameter from another item. Similarly, an RC3 door requires a class C lock.
Consequences of a dimension
A window wider than three metres needs a structural mullion, and one taller than 2.4 metres can come with a surprising transport cost. A door leaf thinner than 68 mm rarely gets a burglar-resistance certificate.
Missing data
A rule will remind you about the opening direction of each sash, or about the frame type when a door with a frame is selected.
A warning does not block saving
Rules come in two levels — warning and information — and none of them stops the measurement. An unusual window is sometimes simply unusual, and we leave the decision to the person on site.

When you need a field of your own

Field sets cannot be edited by you
There is no attribute dictionary screen — the fields are part of the system.

Anything outside the list — a project number, an acoustic parameter, something agreed with the customer — goes in the item note. The note is printed on the measurement document and on the installation order, so it reaches the place where it is needed.

If you miss the same field in every measurement, report it through the Help and requests module in the panel. The field catalogue was built from requests like that and keeps growing that way.