HomeGuidesCondensation and mould after window replacement: who is responsible?
Measurement and installation

Condensation and mould after window replacement: who is responsible?

After new windows go in, water appears on the glass and mould in the corners — and the customer calls with a complaint. Usually the window is fine; the real cause is the ventilation the old, leaky windows used to provide. How to tell three different effects apart, when the showroom is responsible after all, and how to handle the call without a dispute.

Alstre Team9 min read
Autumn, windows and a customer complaint — illustration for an Alstre guide

This is one of the most common complaints in the trade that in fact has nothing to do with a product defect. It is also one where a showroom most easily loses a customer, even though it is right about the windows. The window does exactly what it should, and yet the matter can still land on the seller — just for a different reason than the customer thinks. In this guide we explain why condensation appears precisely after replacement, how to tell apart three quite different effects that customers describe with the same words, when responsibility really does lie with the showroom, how to handle the phone call, and what to put in the quote so the call never happens.

Why the problem only appears after replacement

The old windows leaked air, so all year round they ventilated the flat almost by accident — without the occupants doing anything, and often without them knowing. Moisture from cooking, washing, drying clothes, bathing and simply breathing escaped through gaps in the frames. The same “draught from the sill” that customers complained about kept indoor humidity at a level where nothing condensed.

New windows close that route. Moisture stays inside, the amount of water vapour in the air rises, and it condenses wherever it meets the coldest surface. First on the glass, especially along its bottom edge, and even more readily in the corner of an external wall where the building has a thermal bridge. That is why mould usually appears on the wall or the reveal next to the window rather than on the window itself.

The problem is seasonal. In autumn, while it is still mild outside, walls and glass are relatively warm and the moisture has nowhere to condense. The first frosts chill those surfaces and the effect appears practically overnight — hence the wave of calls straight after the first proper cold snap.

This is not a fault but a side effect of the replacement. The flat has lost the ventilation its leaky windows gave it and has received nothing in return.

Three effects the customer calls “my windows are steaming up”

For the customer, any water on the glass means the windows are “steaming up”. For the showroom these are three different situations with three different answers. It pays to tell them apart on the very first call.

Water on the inside of the glass

The most common case, and the one in the story above. Water settles on the room side, mostly on the lower part of the glass and along the spacer bar; there is most of it in the morning, and it comes back after being wiped off. The cause is excess moisture in the air and too little air exchange in the flat. It is not a window defect — but, as we show below, that does not always mean the showroom has nothing to do with it.

Misting inside the sealed unit

Condensation or streaks between the panes that cannot be wiped off from either side. This is a product defect — the sealed glass unit has lost its seal. The route here is standard: a claim with the manufacturer, plus your own reply to the customer within the time you promised or agreed in the contract. We cover this in more detail in the guide on glass scratches, flaws and condensation.

Dew on the outside of the glass

It looks worrying, but it actually shows the window is very good. Low-emissivity glazing lets almost no heat out of the room, so on a cold, clear night its outer surface cools below the dew point — just like a car roof or the grass. The dew usually disappears within a few hours of sunrise. It is not a defect but proof that the window performs well — and it is worth being able to explain this in one sentence, because customers call about it just as often.

The simplest way to tell them apart is a photo from the customer. If the water can be wiped off from the inside, it is moisture in the flat. From the outside, it is dew. If it cannot be wiped off from either side, the sealed unit has failed. It usually takes a few seconds and one question to the customer.

When the showroom is responsible after all

“The window is working correctly” is true, but it does not close the matter. The customer did not buy just a window — they bought a window replacement in a home they can still live in normally.

For extract ventilation in the kitchen and bathroom to work, fresh outdoor air has to get into the flat: as much air as leaves through the duct must come in from somewhere. Modern windows are so airtight that they no longer provide this supply on their own — so in a flat with natural (passive stack) ventilation it has to be provided in another way, most often with trickle vents in the window frame or air inlets in the wall.

In practice this means one thing: if the showroom sold and installed airtight windows in a flat with natural ventilation without offering trickle vents and without telling the customer about the consequences, there is no product defect, but there is a problem on the showroom's side. Not a fault, but an incomplete service and missing information about something the customer could not have known and a professional should have.

Situations where the showroom's responsibility is practically certain:

  • No trickle vents where they were needed — not offered to the customer and no record that the customer declined them.

  • Ventilation grilles taped over or covered during installation, even by protective film that nobody remembered to remove.

  • Installation that blocked or restricted a ventilation duct or an existing air inlet.

  • A perimeter joint without an internal vapour seal — the foam absorbs moisture, the reveals get cold and mould appears on them even at normal humidity. This is a question of installation quality rather than ventilation.

  • Trickle vents included in the quote but not fitted — that is simply work not done as agreed.

How to handle the call so it doesn't end in a complaint

In this conversation the order matters more than the arguments. The customer calls convinced they were sold a faulty product, and the adviser's first sentence decides whether they keep listening.

Acknowledge the problem first, not the blame. “I understand, this didn't happen before — let's find out where it's coming from” opens the conversation. “The windows are working correctly” shuts it down from the start, even if it is true.

Ask for photos — of the glass, the sill and the corner of the wall, ideally in the morning when there is most water. They show which of the three effects you are dealing with and often let you answer without a site visit.

Explain the physics, not the regulations. Anyone will understand that the old windows aired the flat through the gaps and the new ones no longer do — and this usually changes the customer's attitude completely. Quoting building regulations in the first minute of the call sounds like an attempt to dodge responsibility.

Suggest what the customer can do straight away. Short, intensive airing a few times a day instead of leaving a window on permanent tilt, not covering radiators and sills with long curtains, using the cooker hood while cooking, not drying laundry in a room without airing it, and checking that the bathroom and kitchen vents are not covered. This does not remove the cause, but it quickly reduces the symptoms and shows the showroom is taking the matter seriously.

Offer a solution, not a verdict. Trickle vents can be fitted to windows that are already installed, and it is worth suggesting a check of the ventilation ducts at the same time. That is an offer, not a concession — and if the oversight was on the showroom's side, it is also the simplest way to close the matter without a dispute.

What to do at the sale so this customer never calls with a complaint

A case that blows up in January is in practice decided much earlier — at the measurement and in the quote. Three things are enough.

Ask about ventilation at the on-site measurement. Are there working vents in the flat, is there a draw in the ducts, and were any of them closed off during renovation? The showroom is not responsible for the building's ducts, but knowing they don't work changes everything — including whether to take the order without a written reservation.

Trickle vents as a separate line in the quote — with a price, even if the customer doesn't choose them. An item the customer knowingly declined is a completely different situation from one that was never offered. We explain why a clearly described scope matters in the guide on window quotes.

A short note on ventilation in the contract and the acceptance protocol — that the new windows are airtight, that the flat needs working ventilation, and that without it condensation may appear. One sentence confirmed by the customer's signature is enough. If the windows were installed with an internal vapour seal and an external breathable membrane, note that in the protocol as well.

What information to have at hand when the customer calls

A few months after installation, only what was recorded at the sale counts. For every order it is worth having: whether trickle vents were in the quote and what the customer chose, the ventilation note with the customer's signature, the state of ventilation recorded at the measurement, and photos from the first report.

It is also worth recording the cause of each such report — moisture in the flat, a failed sealed unit or dew on the outside. These cases come back every year with the first frosts. After the season you can see which orders went out without trickle vents, and that is a ready list of customers worth calling in September, before they call you in January.

The Alstre complaints register links each report to the customer's contract, so checking whether trickle vents were in the quote takes a moment instead of searching through a year's worth of emails.

Alstre

All of this happens on its own when documents come out of the system.

The contract template brings in your terms for a private customer or a business, the measurement turns into a quote and the complaint keeps track of the reply deadline.

Condensation on new windows: who is responsible? | Alstre